Friday, 3 March 2017

air circuit breaker
air circuit breaker
A circuit breaker is a device that is used to completely disconnect a circuit when
any abnormal condition exists. The circuit breaker can be designed to actuate
under any undesirable condition.

The purpose of a circuit breaker is to break the circuit and stop the current flow when the current exceeds a predetermined value without causing damage to the circuit or the circuit breaker.

Circuit breakers are commonly used in place of fuses and sometimes eliminate the need for a switch.
 A circuit breaker differs from a fuse in that it "trips" to break the circuit and may be reset, while a fuse melts and must be replaced.

Air circuit breakers (ACBs) are breakers where the interruption of the breaker contacts takes place in an air environment. 



Oil circuit breakers (OCBs) use oil to quench the arc when the breaker contacts open

Low-Voltage Air Circuit Breakers


A low-voltage circuit breaker is one which is suited for circuits rated at 600 volts or lower. One of the most commonly used low-voltage air circuit breakers is the molded case circuit breaker


A cutaway view of the molded case circuit breaker is shown in Figure
cutaway view of the molded case circuit breaker
Fig.cutaway view of the molded case circuit breaker

A circuit can be connected or disconnected using a circuit breaker by manually moving the
operating handle to the ON or OFF position. All breakers, with the exception of very small ones,have a linkage between the operating handle and contacts that allows a quick make (quick break contact action) regardless of how fast the operating handle is moved. The handle is also designed so that it cannot be held shut on a short circuit or overload condition. If the circuit breaker opens under one of these conditions, the handle will go to the trip-free position. The trip-free position is midway between the ON and OFF positions and cannot be re-shut until the handle is pushed to the OFF position and reset.

A circuit breaker will automatically trip when the current through it exceeds a predetermined
value. In lower current ratings, automatic tripping of the circuit breaker is accomplished by use of thermal tripping devices. Thermal trip elements consist of a bimetallic element that can be calibrated so that the heat from normal current through it does not cause it to deflect. An abnormally high current, which could be caused by a short circuit or overload condition, will cause the element to deflect and trip the linkage that holds the circuit breaker shut. The circuit breaker will then be opened by spring action. This bimetallic element, which is responsive to the heat produced by current flowing through it, has an inverse-time characteristic. If an extremely high current is developed, the circuit breaker will be tripped very rapidly.

For moderate overload currents, it will operate more slowly. Molded case breakers with much larger current ratings also have a magnetic trip element to supplement the thermal trip element. The magnetic unit utilizes the magnetic force that surrounds the conductor to operate the circuit breaker tripping linkage.

When the separable contacts of an air circuit breaker are opened, an arc develops between the two contacts. Different manufacturers use many designs and arrangements of contacts and their surrounding chambers. The most common design places the moving contacts inside of an arc chute. The construction of this arc chute allows the arc formed as the contacts open to draw out into the arc chute. When the arc is drawn into the arc chute, it is divided into small segments and quenched. This action extinguishes the arc rapidly, which minimizes the chance of a fire and also minimizes damage to the breaker contacts.
 

Molded case circuit breakers come in a wide range of sizes and current ratings. There are six frame sizes available: 100, 225, 400, 600, 800, and 2,000 amps. The size, contact rating, and current interrupting ratings are the same for all circuit breakers of a given frame size. The continuous current rating of a breaker is governed by the trip element rating. The range of voltage available is from 120 to 600 volts, and interrupting capacity ranges as high as 100,000 amps.
 

Much larger air circuit breakers are used in large commercial and industrial distribution systems. These circuit breakers are available in much higher continuous current and interrupting ratings than the molded case circuit breaker. Breakers of this type have current ratings as high as 4,000 amps, and interrupting ratings as high as 150,000 amps.

Most large air circuit breakers use a closing device, known as a "stored energy mechanism," for fast, positive closing action. Energy is stored by compressing large powerful coil springs that are attached to the contact assembly of a circuit breaker. Once these springs are compressed, the latch may be operated to release the springs, and spring pressure will shut the circuit breaker. Circuit breaker closing springs may be compressed manually or by means of a small electric motor. This type of circuit breaker can be classified as either a manually- or electrically-operated circuit breaker.

When a large air circuit breaker is closed, the operating mechanism is latched. As the circuit breaker is closed, a set of tripping springs, or coils, are compressed, and the circuit breaker may then be tripped by means of a trip latch. The trip latch mechanism may be operated either manually or remotely by means of a solenoid trip coil.
As previously stated, circuit breakers may be operated either manually or electrically.
Electrically-operated circuit breakers are used when circuit
are to be operated at frequent
intervals or when remote operation is required.
circuit breaker operation
circuit breaker

When the electrically-operated stored energy circuit breaker is tripped, the spring is recharged by the spring charging motor so that the breaker is ready for the next closing operation. The manually-operated circuit breaker closing springs are normally compressed by a hand crank just prior to operation of the breaker. Figure  shows a large air circuit breaker which is classified as a manually-operated stored energy circuit breaker. The closing springs are compressed by pulling downward on the large operating handle on the front of the breaker. Closing this circuit breaker is accomplished manually by depressing the small closing lever. Tripping this circuit breaker is done by means of the tripping lever, located at the bottom front of the breaker.



High-Voltage Circuit Breakers
High-voltage circuit breakers (including breakers rated at intermediate voltage) are used for service on circuits with voltage ratings higher than 600 volts. Standard voltage ratings for these circuit breakers are from 4,160 to 765,000 volts and three-phase interrupting ratings of 50,000 to 50,000,000 kVA.

In the early stages of electrical system development, the major portion of high-voltage circuit breakers were oil circuit breakers. However, magnetic and compressed-air type air circuit breakers have been developed and are in use today.
The magnetic air circuit breaker is rated up to 750,000 kVA at 13,800 volts. This type of circuit breaker interrupts in air between two separable contacts with the aid of magnetic blowout coils. As the current-carrying contacts separate during a fault condition, the arc is drawn out horizontally and transferred to a set of arcing contacts. Simultaneously, the blowout coil provides a magnetic field to draw the arc upward into the arc chutes. The arc, aided by the blowout coil magnetic field and thermal effects, accelerates upward into the arc chute, where it is elongated and divided into many small segments.
The construction of this type of circuit breaker is similar to that of a large air circuit breaker used for low-voltage applications, except that they are all electrically operated.

Compressed-air circuit breakers, or air-blast circuit breakers, depend on a stream of compressed air directed toward the separable contacts of the breaker to interrupt the arc formed when the breaker is opened. 
Air-blast circuit breakers have recently been developed for use in extra high-voltage applications with standard ratings up to 765,000 volts.

Oil circuit breakers (OCBs) are circuit breakers that have their contacts immersed in oil. Current interruption takes place in oil which cools the arc developed and thereby quenches the arc. The poles of small oil circuit breakers can be placed in one oil tank; however, the large high-voltage circuit breakers have each pole in a separate oil tank. The oil tanks in oil circuit breakers are normally sealed. 
The electrical connections between the contacts and external circuits are made
through porcelain bushings.


Circuit Breaker Control
As we have discussed, circuit breakers may be remotely operated. In order to operate the breakers from a remote location, there must be an electrical control circuit incorporated. Figure shows a simple control circuit for a remotely-operated breaker.
Simple Circuit Breaker Control Circuit open
Simple Circuit Breaker Control Circuit open
Control power is supplied by an AC source and then rectified to DC. The major components of a simple control circuit are: the rectifier unit, the closing relay, the closing coil, the tripping coil,the auxiliary contacts, and the circuit breaker control switch.



To close the remotely-operated circuit breaker, turn the circuit breaker control switch to the close position. This provides a complete path through the closing relay (CR) and energizes the closing relay. The closing relay shuts an auxiliary contact, which energizes the closing coil (CC), which, in turn, shuts the circuit breaker, as shown in Figure . The breaker latches in the closed position. Once the breaker is shut, the "b" contact associated with the closing relay opens,
de-energizing the closing relay and, thereby, the closing coil. When the breaker closes, the "a"contact also closes, which enables the trip circuit for manual or automatic trips of the breaker.
Simple Circuit Breaker Control Circuit closed
Simple Circuit Breaker Control Circuit closed

The circuit breaker control switch may now be released and will automatically return to the
neutral position.
To open the circuit breaker, turn the circuit breaker control switch to the trip position. This
action energizes the trip coil (TC), which acts directly on the circuit breaker to release the
latching mechanism that holds the circuit breaker closed.

When the latching mechanism is released, the circuit breaker will open, opening the "a" contact
for the tripping coil and de-energizing the tripping coil. Also, when the circuit breaker opens,
the "b" contact will close, thereby setting up the circuit breaker to be remotely closed using the
closing relay, when desired. The circuit breaker control switch may now be released.
As you can see from Figure the circuit breaker control circuit can be designed so that any
one of a number of protective features may be incorporated. The three most commonly-used automatic trip features for a circuit breaker are overcurrent (as discussed previously),
underfrequency, and undervoltage. If any one of the conditions exists while the circuit breaker is closed, it will close its associated contact and energize the tripping coil, which, in turn, will trip the circuit breaker.

REFERENCE:DOE FUNDAMENTALS HANDBOOK
ELECTRICAL SCIENCE

Monday, 20 February 2017

explanation about protection provided to induction and other types motor are given below:
In order to avoid unexpected breakdowns, costly repairs and subsequent losses due to motor downtime, it is important that the motor is fitted with some sort of protective device. Generally speaking,

Motor protection can be divided into the following 3 levels:

• External protection against short circuit in the whole installation. External protection device is normally different types of fuses or short circuit relays. This kind of protection device is compulsory and legal and placed under safety regulations.

• External protection against overload of specific equipment; i.e. to avoid overload of
pump motor and thereby prevent damage
and breakdown of the motor. This type of
protection reacts on current.

• Built-in motor protection with thermal
overload protection to avoid damage and
breakdown of motor. The built-in protector
always require an external circuit breaker
while some built-in motor protection types
even require an overload relay 
list of the most common fault conditions where motor damage can be avoided by some sort of motor protection:
• Problems with the power supply quality:
– Overvoltage
– Undervoltage
– Imbalanced voltages/currents
– Frequency variation
• Installation, supply & motor failures
• Slowly developing temperature rise:
– Insufficient cooling
– High ambient temperature
– High altitude operation
– High liquid temperature
– Too high viscosity of the pumping liquid
– Frequent starts
– Too big load inertia
– (not common for pumps)
• Quickly developing temperature rises:
– Locked rotor
– Phase breakage

To protect a circuit against overloads and short circuits, a circuit protective device must determine when one of these fault conditions occurs.It must then automatically disconnect the circuit from the power source. A fuse is the simplest device for accomplishing these two functions.

Normally fuses are built together by means of
a safety switch, which can switch off the circuit.

In this post, we will discuss three
types of fuses as per their function and to where they are used: 
Fusible safety switch, “quick-acting” fuse and “time-lag” fuse

Fusible safety switch:
A fusible safety switch is a safety switch, which is combined with a fuse in a single enclosure. The switch manually opens and closes the circuit, while the fuse protect against overcurrent protection.Switches are generally used in connection with
service when it is necessary to cut off the current, or in connection with fault situations.
The safety switch is a switch, which is placed 
in a separate enclosure. The enclosure protects personnel against accidental exposure to electrical connections and against exposure to weather conditions. Some safety switches come with a built-in function for fuses, and some safety switches come without built-in fuses, containing only a switch.
The overcurrent protection device (fuse) has to
recognise the difference between overcurrent
and short circuit. Slight overcurrents for 

example, can be allowed to continue for a short period of time. But as the current magnitude increases, the protection device has to react quickly. It is important to interrupt short circuits immediately.
The fusible disconnect switch is an example of a device which is used for overcurrent protection.Properly sized fuses in the switch open the circuit when an overcurrent condition occurs.

Quick-acting:
"Quick-acting” fuses Nontime-delay fuses provide excellent short circuit protection. However, brief overloads, such as motor starting currents, may cause problems for this kind of fuse. Therefore, nontime-delay fuses are best used in circuits, which are not  subject to large transient currents. Normally, nontime-delay fuses hold some 500% of their rated current for one-fourth of a second. After this time, the current-carrying element melts, and opens the fuse.Thus, in motor circuits, where the starting current often exceeds 500% of the fuse’s rated current, nontime-delay fuses are not recommended.

“Time-lag” fuses:
This kind of fuse provides both overload and short-circuit protection. Typically, they allow up to 5 times the rated current for up to 10 seconds and for shorter periods even higher currents. Usually, this is sufficient to allow a motor to start without opening the fuse. On the other hand, if an overload condition occurs and persists for a longer period of time, the fuse will eventually open.

Reference:Motor Book Grundfos


Monday, 30 January 2017


Different types of Induction motor protection given below:

Introduction of motor protection:
Electric motors are exposed to many kinds of disturbances and stress. Part of the disturbances is due to imposed external conditions such as over voltage and undervoltage, over frequency and underfrequency, harmonics, unbalanced system voltages and supply interruptions,  Other possible causes of external disturbances are dirt in the motor, cooling system and bearing failures or increase of ambient temperature and humidity. Stress on motor due to frequent successive startups,overload situations including mechanical stress. The above stress and disturbances deteriorate the winding insulation of the motor mechanically and by increased thermal ageing rate, which may eventually lead to an insulation failure.
The purpose of the motor protection is to limit the effects of the disturbances and stress factors to a safe level, for example, by limiting overvoltages or by preventing too frequent startup attempts. If, however, a motor failure takes place, the purpose of the protection is to disconnect the motor from the supplying network in due time
Motor overload condition is mainly a result from abnormal use of the motor, harmonics or unbalanced supply voltages. They all increase the motor losses and cause additional heating. As the temperature exceeds the rated limits specified for the insulation class, the winding insulation deterioration startup. This will reduced the expected lifetime of the motor and may lead to an electrical fault in the winding. Thus, the thermal overload protection can be
considered being the most important protection function

2) Thermal Model 
The thermal behavior of the stator and the rotor during startups and during constant overload situations differs significantly from each other. Due to this fact, the dynamics of the motor heating and cooling is typically designed separately for the stator and for the rotor of motor. Designing the thermal overload protection in this way, it can be set to follow the thermal state of the motor optimally, and good and accurate protection against both short and long-time overload conditions can be accomplished, which allows the full use of the available capacity.

3) Frequent Startup Supervision:

In order avoid, shorten the expected lifetime of the motor, there must be an adequate time interval between successive startups of motors. Therefore, a certain starting frequency, that is, the number of startups per hour specified for the motor, must not be exceeded.Especially during successive startups, the temperature of the rotor rises and drops rapidly whereas the temperature of the stator changes much more slowly. At rated load, the temperature of the rotor is much lower than the temperature of the stator.If after a startup the motor is running for some time before stopping, the rotor has enough time to cool down. Then whether a restart can be done or not depends totally on the stator temperature, which can be a limiting factor. On the other hand, if the initial start had been done from a cold condition and it failed for
some reason, then whether a restart can be done or not depends now totally on the rotor temperature, which can be a limiting factor instead. If the initial start had been done from hot condition, then the limiting factor is again the stator temperature. this kind of thermal behavior simulated with the two-time-constant model for the stator and for the rotor.


4) Overload Protection
A minor overload does not cause a motor failure immediately but it will eventually shorten the expected lifetime. On the other hand, a constant overload can be a sign of some kind of disturbance in the process in which the motor drive is being used. Thus, a two-stage overload protection is preferred. The alarming stage gives an indication that the rated load of the motor with a possible margin has been exceeded. This function can be implemented by a pre-warning temperature level setting in the thermal model. The pre-warning alarm gives the operator some time to find out the possible source of the overload and to attempt to remove it. If the overload becomes higher, for example 10-15%, the tripping stage starts and trips the motor feeder in due time unless the source of the overload has disappeared before that. According to the thermal model,tripping takes place when the estimated thermal level exceeds 100%. shows an example of the thermal behavior when the motor is running on a constant cyclic overload. These curves have been simulated using the two-time-constant model for the stator and for the rotor. In this case, the prewarninglevel is exceeded and the operator is notified. As a result, the tripping is prevented as the loading of the motor becomes suitably reduced. It can also be concluded from that a comprehensive overload protection in fact requires the use of the two-time-constant model for the rotor and for the stator, and in this way, the full utilization of the available capacity of the motor is ensured. However, adequate protection can also be implemented using the single-time-constant model, which is set to allow the normal use of the motor drive with a suitable margin
 

5)Overheating Protection
The motor temperature can rise above the rated values allowed for the stator and for the rotor even if the motor is not actually being overloaded. Possible reasons for this are dirt in the motor, failures in the cooling system or harmonic currents. Especially in case of variable frequency drives, overheating may take place if the motor is being loaded with rated current simultaneously with low rotating speed because of the increased losses and reduced cooling.

i) Stator Earth-fault Protection

As the winding insulation deteriorates due to ageing processes, instantly imposed severe thermal or mechanical stress may exceed the withstanding level, leading to an insulation breakdown. Usually, this results in an earth fault, where the fault current flows through the stator iron plates. If the current is less than 10A,only alarming protection can typically be considered. With a higher fault, current tripping is recommended as the damages to the stator iron may become substantial. 

ii) Short Circuit and Inter-winding Fault Protection:
Sustained earth fault in the motor can develop to a short circuit fault between the phase windings. Another possible cause is the out-of-phase re-energizing during autoreclosing when high mechanical stress may shake and vibrate the windings so that the insulation between the windings breaks. This kind of fault must be tripped as fast as possible to minimize further damages. Usually a high-set overcurrent stage is used for the protection. This function also constitutes the short circuit protection of the supplying cable. Also with bigger machines, differential protection can be considered if the neutral point with suitable CTs are available.

Working principle of full wave bridge rectifier and digram

Full wave bridge rectifier - Rectifier is a circuit which convert alternating voltage into the direct voltage. There are three types o...